Hydraulic Filter Press
News
  • Filter Press Usage Attention
    May 28, 2020

    Don’t put the hydraulic filter press outside of the house:1. Adding the hydraulic oil (46#) to the oil box and gear box.2. Connecting the electric wire and oil tubes, match with the same number.3. The operator should spread the lubricant on the chain.4. Confirming the electric motor rotating in the correct direction.5. Before the usage, testing the chamber filter press for several times to make sure that the gear box full of hydraulic oil.6. Before delivering the machine, we have fixed the working pressure, so don’t adjust the working pressure if no necessary. If necessary, please make sure that the maxi pressure (red line) of the gauge (13Mpa) should be lower than the hydraulic system maxi pressure (black line) ( 17Mpa). The mini pressure of gauge (green needle) is 10Mpa. If the gauge maxi pressure (red line) more than the system pressure, the motor will start up and working all the time, then the motor will be broken if nobody find this problem.7. Please noted if the shifter could not advance or stop, it’s because the sensor is not facing the gear,it should be put facing the gear part, so it could control the shifter to advance or stop.8. The stainless steel tube is an emergency stop for the plate shifter, just pull and release could control the shifter stop or work again. This design is for checking shifter or for worker have enough time for discharging the filtered cakes.9. In the shifter device, the screws should be locked in the suitable tightness, so it could work normally. Too tight, it could not be up to shift the plates.10. During the testing for returning, there will be some noise, it’s the reason that filter plates have no slurry full or the oil cylinder has air. 

    Read More
  • Filter Press and Piston Pump Usage Testing
    May 28, 2020

    1. Confirm whether all the plate filter press and ceramic plunger pump has been added hydraulic oil, whether all the electricity are connected (please noted that the electricity is 380V, three phase), whether all the tube is tightened.2. Please be carefull when check the electricity.3. Install the overtravel-limit switch for the plate filter press4. Start the filter press machine, check whether the pressure of filter press could reach 15Mpa, the green line should be 10Mpa, the red line should be 15Mpa. If the pressure could not reach 15Mpa, please use the over-flow valve to adjust the pressure.5. If the working pressure is normal, please press the return button, check all the cloth, and promise they are in good condition, not be folded, and be smoothy.6. If the cloth is in good condition, please press the start button, press the plates tightly.7. Confirm all the valve is closed.8. For the ceramic piston pump, please check whether the slurry input tube is working in good condition of airtightness. If this tube has no good air-tightness, the air will go in and affect the working pressure of pump, and let the pump could not transport the slurry.9. Open the tap, let the water from the tap cooling the pistons all the time when the ceramic plunger pump is working, to protect the ceramic pistons.10. For the first time to use the ceramic piston pump, you need to open the two valves which are below the air tank, to remove the air in the pump, so the pump could transport the slurry quickly and easily.11. After checking all the valve of sludge pump is closed, start up the sludge pump to transport the slurry.12. If you find that no water be filtered out, but the ceramic plunger pump is still working, this is may the reason that the ceramic piston pump could not absorbe the slurry. In this situation, please stop the ceramic plunger pump, to check the valve boxs whether there is any big particles to stop the rubber balls.13. The slurry input tube should be the soft tube, so that they could be easily moved anytime and anywhere. We also recommend the woker to tie a thread on the tail of this tube, which will be conveniently for them to move the tube to promise that the tube is in the right place of slurry.14.  For the filtration, the water filtered out will be relative uncleaning, but this is normal phenomenon, this is may be caused by the folded cloth, or may be caused by the plastic bolts which is not tightened well.15. How to confimed that the filtration is finished:  A. check whether the working pressure of pump is reach 1.5 Mpa.  B. check whether the two ceramic pistons are woking slowly.16. If confiming that the filtration is finished, please stop the electricity, open the valve of slurry input tube to remove the pressure. After removing the pressure, please press the return the button and unload the filtered cakes.17.  After finished the unloading, after checking all the valves are closed tightly, then you could start the new filt...

    Read More
  • Ceramic Plunger Pump Advantage
    Oct 14, 2021

    Ceramic Plunger Pump Advantage1. Wear resistance: The plunger is made of alumina ceramics which is finely ground and it hardness is above HLC8.5 and the surface roughness is 0.4um. The plunger and the conveyed materials have no shearing movement which is suitable for conveying materials containing sand and solid particles.  2. Strong self-priming ability: plunger-type vacuuming method, self-priming capacity of 4-8 meters (the specific gravity of the material determines the change of the suction range)      3. Adjustable constant pressure and automatic variable flow: The working pressure of the piston mud pump is adjustable, and it can be adjusted arbitrarily within the range of 0-20 kg. The adjusted pressure will not change due to the change of the output flow of the pump, and the set pressure will be maintained. Even if the outlet of the running pump is shut down, the pressure will not change. (The change cannot exceed the large flow rate of the pump, the flow rate can be zero).     4. High pressure is effective: the normal model has a higher pressure of 20 kg. When the pressure is ≥ 5 kg and the flow rate is the same, the power of the plunger mud pump motor is 1 to 2 models lower than other types of pumps.     5. Easy operation: only need to tighten or loosen the pressure regulating valve to adjust the pressure. After the pressure is adjusted, it will be locked, and there is no need to adjust it in the future.     6. Low cost of use: the vulnerable parts of the pump are the valve plate and plunger seal. The replacement cycle of the ceramic slurry is 3-6 months, and the municipal sludge is 6-12 months.      7. Long service life: The service life is at least 15 years.     8. Customized production: According to the actual working conditions of each user, it can be flexibly configured and customized products suitable for customers' production needs.

    Read More
1 ... 9 10 11 12 13 14 15 16
A total of16pages

Subscribe For Newsletter

For inquiries about our products or pricelist, please leave to us and we will be in touch within 24 hours.

leave a message
leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

About

Contact